The TRANSITION Networks Ethernet™ Coaxial Transceiver (E-CX-MC02, E-CX-MC03,
E-CX-MC04, or E-CX-MC05) is designed to provide connection between the Thick
(10Base5) or Thin (10Base2) coaxial Ethernet environment and a PC or hub with an
AUI connector.
Ethernet Coaxial Transceiver
E-CX-MC02, E-CX-MC03, E-CX-MC04, E-CX-MC05
USER’S GUIDE
FCC Regulations:
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses, and
can radiate radio frequency energy and, if not used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the interference at his own cost.
NOTE: This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out
on the radio interference regulations of the Canadian Department of Communications.
NOTE: This equipment has been tested and found to comply with VDE Class B requirements.
For selling in the Federal Republic of Germany:
Hiermit wird bescheinigt, das der E-FRL-MC01 oder E-FRL-MC01(SMA) in Ubereinstimmung mit den
Bestimmungen der Vfg. 243/1991 funk-entstoert ist. Der Deutschen Bundespost wurde das
Inverkehgringen dieses Geraetes angezeigt und die Berechtigung zur Ueberpruefung der Serie auf
Einhaltung der Bestimmungen eingeraumt. TRANSITION Networks, Inc.
Canadian Regulations:
Note: This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the
radio interference regulations of the Canadian Department of Communications.
Copyright Restrictions
© 1995 Transition Networks, Inc.
All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic,
electronic, or mechanical - without written permission from Transition Networks, Inc.
Trademarks:
Ethernet is a registered trademark of the Xerox Corporation, Inc.
ST is a trademark of AT&T.
TRANSITION Networks and Micro-Ceiver are trademarks of TRANSITION Networks 7315 E
Specifications:
Case size dimensions: 3.5" x 3.75" x 1.25" (89 mm x 95 mm x 32 mm)
AUI Port: Male DB-15 with locking posts.
AUI Connection: Use only an IEEE 802.3 equivalent AUI
cable.
Connector Legend: 1 Logic Ref. 9 Collision-
2 Collision+ 10 Transmit-
3 Transmit+ 11 Logic Ref.
4 Logic Ref. 12 Receive-
5 Receive+ 13 Power
6 Power Return 14 Logic Ref.
7 N/C 15 N/C
8 Logic Ref.
AUI Drop Cable Maximum Distance: 50 meters (165 feet)
10Base5 Cable Maximum Distance: 500 meters (1640 feet)
10Base2 Cable Maximum Distance: 185 meters (610 feet)
Environment: 0–50 degrees C,
10–90% humidity, non-condensing,
0–10,000 foot altitude
Warranty: Five years
Minneapolis, MN 55344 USA
Status LEDs on the Ethernet Coaxial Transceiver provide the following
information:
The TRANSITION Networks Ethernet™ Coaxial Transceiver part numbers indicate
the AMP tap that is shipped with the Coaxial Transceiver:
E-CX-MC02: with AMP non-intrusive tap 228752-1
E-CX-MC03: with AMP N-Series intrusive tap, 221914-1
E-CX-MC04: with AMP BNC-T connector 221918-1
E-CX-MC05: with AMP BNC vertical adapter 222455-1
All Ethernet™ Coaxial Transceivers provide a male AUI connector.
Power: Illuminated green LED indicates power through the
AUI connector.
SQE Enabled Illuminated green LED indicates the SQE jumper is set
to ON.
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - Ethernet Coaxial Transceiver

SQE EnabledPowerEthernet™CoaxialTransceivernetworksTRANSITIONMpls, MN 55344The TRANSITION Networks Ethernet™ Coaxial Transceiver (E-CX-MC02, E-CX-MC03

Seite 2 - Installation Notes

SQE "OFF"NETWORKSQE "ON"SQE EnabledPowerEthernet™CoaxialTransceivernetworksTRANSITIONMpls, MN 55344networksTRANSITIONMpls, MN 5534

Kommentare zu diesen Handbüchern

Keine Kommentare