E-TX-FX-XX00 IN THE NETWORK
Each media converter port in the multi-port media converter operates
independently over one isolated twisted-pair copper/fiber-optic cable
link. The media converter port receives and transmits network signals in
either full-duplex or half-duplex, depending upon the network devices
to which the media converter port is attached.
NOTE: In Telco option (not shown), the 50-pin Telco connector
concentrates up to 12 UTP connections onto one connector. This
concentration of UTP ports is then broken out for connection to fiber.
RJ-45 CONNECTOR
Twisted pair connection requires two active pairs configured as straight
through and/or crossover. The two active pairs in an Ethernet™ network are
pins 1 & 2 and pins 3 & 6. Use only dedicated wire pairs (such as blue/white
& white/blue, orange/white & white/orange) for the active pins.
NOTE: The multi-port media converter AutoCross™ feature allows either straight-
through or crossover twisted-pair copper cable to be used when connecting to
10BASE-T devices. AutoCross™ determines the characteristics of cable
connections to the media converter port and then automatically configures the
port to link up.
TECHNICAL SPECIFICATIONS
Standards IEEE 802.3 1998 Edition
Case Dimensions 19.0" x 8.5" x 1.5" (483 mm x 216 mm x 38 mm)
Environment Temperature: 0-50°C (32° to 122° F )
Humidity 10-95%, non condensing
Altitude 0-10,000 feet
Power 100-240 VAC, 50/60 Hz., 1 Amp (maximum)
Warranty Lifetime
DECLARATION OF CONFORMITY
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA
Model: E-TX-FX-xx00, E-TEL-xx00 Series Multi-Port Media Converter
Part Number(s): E-TX-FX-0600, E-TX-FX-0600(SC), E-TX-FX-0600(SM), E-TX-FX-0600(LH),
E-TX-FX-0600(MT), E-TX-FX-1200, E-TX-FX-1200(SC), E-TX-FX-1200(SM),
E-TX-FX-1200(LH), E-TX-FX-1200(MT), E-TEL-1200, E-TEL-1200(SC),
E-TEL1200(SM), E-TEL-1200(LH), E-TEL-1200(MT)
Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the E-TX-FX-0600, E-TX-FX-1200 or E-TEL-1200 to
which this declaration refers is in conformity with the following standards.
EMC-CISPR 22: 1985 Class A; EN 55022: 1988 Class A; EN 50082-1:1992;
EN 60950 A4:1997; IEC 801.2, IE C 801.3, and IEC 801.4; IEC 950
I, the undersigned, hereby declare that the equipment specified above conforms to the
above Directive(s) and Standard(s).
_September 3, 1999_____
Stephen Anderson, Vice-President of Engineering Date